-static int pcl818_check(struct comedi_device *dev)
-{
-       /* the MUX register should return the same value written */
-       outb(0x00, dev->iobase + PCL818_MUX);
-       if (inb(dev->iobase + PCL818_MUX) != 0x00)
-               return -ENODEV;
-       outb(0x55, dev->iobase + PCL818_MUX);
-       if (inb(dev->iobase + PCL818_MUX) != 0x55)
-               return -ENODEV;
-
-       /* reset the MUX register to a known state */
-       outb(0x00, dev->iobase + PCL818_MUX);
-
-       /* the CONTROL register should return the same value written */
-       outb(0x18, dev->iobase + PCL818_CONTROL);
-       if (inb(dev->iobase + PCL818_CONTROL) != 0x18)
-               return -ENODEV;
-
-       /* reset the CONTROL register to a known state */
-       outb(0x00, dev->iobase + PCL818_CONTROL);
-
-       return 0;
-}
-
 static int pcl818_attach(struct comedi_device *dev, struct comedi_devconfig *it)
 {
        const struct pcl818_board *board = comedi_board(dev);
        if (ret)
                return ret;
 
-       ret = pcl818_check(dev);
-       if (ret)
-               return ret;
-
        /* we can use IRQ 2-7 for async command support */
        if (it->options[1] >= 2 && it->options[1] <= 7) {
                ret = request_irq(it->options[1], interrupt_pcl818, 0,