From: Sage Weil Date: Tue, 18 Apr 2017 17:54:56 +0000 (-0400) Subject: mon/PGMonitor: clean up min/max span warning X-Git-Tag: v12.0.3~272^2 X-Git-Url: http://git-server-git.apps.pok.os.sepia.ceph.com/?a=commitdiff_plain;h=489e810c37ed6fb9d32d1015634041a577501ee4;p=ceph.git mon/PGMonitor: clean up min/max span warning Clean up option naming. Signed-off-by: Sage Weil --- diff --git a/src/common/config_opts.h b/src/common/config_opts.h index ae6fdf2ccb38..f238ed65362b 100644 --- a/src/common/config_opts.h +++ b/src/common/config_opts.h @@ -318,7 +318,7 @@ OPTION(mon_crush_min_required_version, OPT_STR, "firefly") OPTION(mon_warn_on_crush_straw_calc_version_zero, OPT_BOOL, true) // warn if crush straw_calc_version==0 OPTION(mon_warn_on_osd_down_out_interval_zero, OPT_BOOL, true) // warn if 'mon_osd_down_out_interval == 0' OPTION(mon_warn_on_cache_pools_without_hit_sets, OPT_BOOL, true) -OPTION(mon_warn_osd_usage_percent, OPT_FLOAT, .40) // warn if difference in usage percent between OSDs exceeds specified percent +OPTION(mon_warn_osd_usage_min_max_delta, OPT_FLOAT, .40) // warn if difference between min and max OSD utilizations exceeds specified amount OPTION(mon_min_osdmap_epochs, OPT_INT, 500) OPTION(mon_max_pgmap_epochs, OPT_INT, 500) OPTION(mon_max_log_epochs, OPT_INT, 500) diff --git a/src/mon/PGMonitor.cc b/src/mon/PGMonitor.cc index 6669ffcd4b35..35685352d2af 100644 --- a/src/mon/PGMonitor.cc +++ b/src/mon/PGMonitor.cc @@ -1454,21 +1454,26 @@ void PGMonitor::get_health(list >& summary, } } - if (g_conf->mon_warn_osd_usage_percent) { - float max_osd_perc_avail = 0.0, min_osd_perc_avail = 1.0; + if (g_conf->mon_warn_osd_usage_min_max_delta) { + float max_osd_usage = 0.0, min_osd_usage = 1.0; for (auto p = pg_map.osd_stat.begin(); p != pg_map.osd_stat.end(); ++p) { // kb should never be 0, but avoid divide by zero in case of corruption if (p->second.kb <= 0) continue; - float perc_avail = ((float)(p->second.kb - p->second.kb_avail)) / ((float)p->second.kb); - if (perc_avail > max_osd_perc_avail) - max_osd_perc_avail = perc_avail; - if (perc_avail < min_osd_perc_avail) - min_osd_perc_avail = perc_avail; + float usage = ((float)p->second.kb_used) / ((float)p->second.kb); + if (usage > max_osd_usage) + max_osd_usage = usage; + if (usage < min_osd_usage) + min_osd_usage = usage; } - if ((max_osd_perc_avail - min_osd_perc_avail) > g_conf->mon_warn_osd_usage_percent) { + float diff = max_osd_usage - min_osd_usage; + if (diff > g_conf->mon_warn_osd_usage_min_max_delta) { ostringstream ss; - ss << "Difference in osd space utilization " << ((max_osd_perc_avail - min_osd_perc_avail) *100) << "% greater than " << (g_conf->mon_warn_osd_usage_percent * 100) << "%"; + ss << "difference between min (" << roundf(min_osd_usage*1000.0)/100.0 + << "%) and max (" << roundf(max_osd_usage*1000.0)/100.0 + << "%) osd usage " << roundf(diff*1000.0)/100.0 << "% > " + << roundf(g_conf->mon_warn_osd_usage_min_max_delta*1000.0)/100.0 + << " (mon_warn_osd_usage_min_max_delta)"; summary.push_back(make_pair(HEALTH_WARN, ss.str())); if (detail) detail->push_back(make_pair(HEALTH_WARN, ss.str()));