From cbeab5c566843a44899b2d4eb0be59a0e7cf070b Mon Sep 17 00:00:00 2001 From: Paul Cuzner Date: Thu, 27 Jan 2022 11:24:34 +1300 Subject: [PATCH] monitoring: remove old MIB The MIB file that matches the OID definitions in the alerts is CEPH-MIB.txt. The old MIB from the original SuSE snmp gateway work, therefore needs to be removed to avoid confusion. Signed-off-by: Paul Cuzner --- monitoring/snmp/CEPH-PROMETHEUS-ALERT-MIB.txt | 377 ------------------ 1 file changed, 377 deletions(-) delete mode 100644 monitoring/snmp/CEPH-PROMETHEUS-ALERT-MIB.txt diff --git a/monitoring/snmp/CEPH-PROMETHEUS-ALERT-MIB.txt b/monitoring/snmp/CEPH-PROMETHEUS-ALERT-MIB.txt deleted file mode 100644 index 0eeda4471cb7d..0000000000000 --- a/monitoring/snmp/CEPH-PROMETHEUS-ALERT-MIB.txt +++ /dev/null @@ -1,377 +0,0 @@ -CEPH-PROMETHEUS-ALERT-MIB DEFINITIONS ::= BEGIN - -IMPORTS - MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises, TimeTicks - FROM SNMPv2-SMI - DisplayString - FROM SNMPv2-TC -; - -ceph OBJECT IDENTIFIER ::= { enterprises 50495 } -prometheus OBJECT IDENTIFIER ::= { ceph 15 } - -prometheusAlert MODULE-IDENTITY - LAST-UPDATED "201904010000Z" -- 1. Apr 2019 - ORGANIZATION "The Ceph Project" - CONTACT-INFO "https://ceph.com" - DESCRIPTION "Prometheus Alert SNMP MIB" - REVISION "201904010000Z" -- 1. Apr 2019 - DESCRIPTION "Initial version." - ::= { prometheus 1 } - -prometheusAlertObjects OBJECT IDENTIFIER ::= { prometheusAlert 1 } -prometheusAlertTraps OBJECT IDENTIFIER ::= { prometheusAlert 2 } - --- --- Objects --- - -prometheusAlertNotificationAlertName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "The name of the Prometheus alert." -::= { prometheusAlertObjects 1 } - -prometheusAlertNotificationStatus OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "The status of the Prometheus alert." -::= { prometheusAlertObjects 2 } - -prometheusAlertNotificationSeverity OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "The severity of the Prometheus alert." -::= { prometheusAlertObjects 3 } - -prometheusAlertNotificationInstance OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "Unique identifier for the Prometheus instance." -::= { prometheusAlertObjects 4 } - -prometheusAlertNotificationJob OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "The name of the Prometheus job." -::= { prometheusAlertObjects 5 } - -prometheusAlertNotificationDescription OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "The Prometheus alert description field." -::= { prometheusAlertObjects 6 } - -prometheusAlertNotificationLabels OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "Additional Prometheus alert labels as JSON string." -::= { prometheusAlertObjects 7 } - -prometheusAlertNotificationTimestamp OBJECT-TYPE - SYNTAX TimeTicks - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "The time when the Prometheus alert occurred." -::= { prometheusAlertObjects 8 } - -prometheusAlertNotificationRawData OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION "The raw Prometheus alert as JSON string." -::= { prometheusAlertObjects 9 } - --- --- Traps --- - -prometheusAlertTrapDefault NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "Default trap." -::= { prometheusAlertTraps 1 } - -prometheusAlertClusterHealthTraps OBJECT IDENTIFIER ::= { prometheusAlertTraps 2 } -prometheusAlertMonTraps OBJECT IDENTIFIER ::= { prometheusAlertTraps 3 } -prometheusAlertOsdTraps OBJECT IDENTIFIER ::= { prometheusAlertTraps 4 } -prometheusAlertMdsTraps OBJECT IDENTIFIER ::= { prometheusAlertTraps 5 } -prometheusAlertMgrTraps OBJECT IDENTIFIER ::= { prometheusAlertTraps 6 } -prometheusAlertPgsTraps OBJECT IDENTIFIER ::= { prometheusAlertTraps 7 } -prometheusAlertNodesTraps OBJECT IDENTIFIER ::= { prometheusAlertTraps 8 } -prometheusAlertPoolsTraps OBJECT IDENTIFIER ::= { prometheusAlertTraps 9 } - -prometheusAlertClusterHealthTrapHealthError NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "Ceph in health_error state for more than 5m." -::= { prometheusAlertClusterHealthTraps 1 } - -prometheusAlertClusterHealthTrapHealthWarn NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "Ceph in health_warn for more than 15m." -::= { prometheusAlertClusterHealthTraps 2 } - -prometheusAlertMonTrapLowMonitorQuorumCount NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "Monitor count in quorum is low." -::= { prometheusAlertMonTraps 1 } - -prometheusAlertOsdTrap10PercentOsdsDown NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "More than 10% of OSDs are down." -::= { prometheusAlertOsdTraps 1 } - -prometheusAlertOsdTrapOsdDown NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "One or more OSDs down for more than 15 minutes." -::= { prometheusAlertOsdTraps 2 } - -prometheusAlertOsdTrapOsdsNearFull NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "An OSD is dangerously full, over 80%." -::= { prometheusAlertOsdTraps 3 } - -prometheusAlertOsdTrapFlapOsd NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "An OSD was marked down at back up at least once a minute for 5 minutes." -::= { prometheusAlertOsdTraps 4 } - -prometheusAlertOsdTrapHighPgCountDeviation NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "An OSD deviates by more then 30% from average PG count." -::= { prometheusAlertOsdTraps 5 } - -prometheusAlertPgsTrapPgsInactive NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "One or more PGs are inactive for more than 5 minutes." -::= { prometheusAlertPgsTraps 1 } - -prometheusAlertPgsTrapPgsUnclean NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "One or more PGs are not clean for more than 15 minutes." -::= { prometheusAlertPgsTraps 2 } - -prometheusAlertNodesTrapRootVolumeFull NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "Root volume (OSD and MON store) is dangerously full (< 5% free)." -::= { prometheusAlertNodesTraps 1 } - -prometheusAlertNodesTrapNetworkPacketsDropped NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "A node experiences packet drop > 1 packet/s on an interface." -::= { prometheusAlertNodesTraps 2 } - -prometheusAlertNodesTrapNetworkPacketErrors NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "A node experiences packet errors > 1 packet/s on an interface." -::= { prometheusAlertNodesTraps 3 } - -prometheusAlertNodesTrapStorageFilling NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "A mountpoint will be full in less then 5 days assuming the average fillup rate of the past 48 hours." -::= { prometheusAlertNodesTraps 4 } - -prometheusAlertPoolsTrapPoolFull NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "A pool is at 90% capacity or over." -::= { prometheusAlertPoolsTraps 1 } - -prometheusAlertPoolsTrapPoolFillingUp NOTIFICATION-TYPE - OBJECTS { - prometheusAlertNotificationAlertName, - prometheusAlertNotificationStatus, - prometheusAlertNotificationSeverity, - prometheusAlertNotificationInstance, - prometheusAlertNotificationJob, - prometheusAlertNotificationDescription, - prometheusAlertNotificationLabels, - prometheusAlertNotificationTimestamp, - prometheusAlertNotificationRawData - } - STATUS current - DESCRIPTION "A pool will be full in less then 5 days assuming the average fillup rate of the past 48 hours." -::= { prometheusAlertPoolsTraps 2 } - -END -- 2.39.5