From f8a8a5663842bbcbf343219733c4c8b2da29225b Mon Sep 17 00:00:00 2001 From: Radoslaw Zarzynski Date: Wed, 30 Jul 2025 12:13:06 +0200 Subject: [PATCH] monc: synchronize tick() of MonClient with shutdown() For RCA please refer to: https://tracker.ceph.com/issues/67244#note-11. Fixes: https://tracker.ceph.com/issues/67244 Signed-off-by: Radoslaw Zarzynski (cherry picked from commit 4d65098c874e8548711da9d04b274e8ef0e88922) --- src/mon/MonClient.cc | 5 +++++ 1 file changed, 5 insertions(+) diff --git a/src/mon/MonClient.cc b/src/mon/MonClient.cc index acda4f6d3914..6cb43c00a979 100644 --- a/src/mon/MonClient.cc +++ b/src/mon/MonClient.cc @@ -963,6 +963,11 @@ void MonClient::tick() { ldout(cct, 10) << __func__ << dendl; + if (stopping) { + ldout(cct, 1) << "skipping tick on shutdown" << dendl; + return; + } + utime_t now = ceph_clock_now(); auto reschedule_tick = make_scope_guard([this] { -- 2.47.3