mointoring: Add hardware alerts 69757/head
authorAfreen Misbah <afreen@ibm.com>
Thu, 2 Jul 2026 09:21:19 +0000 (14:51 +0530)
committerAfreen Misbah <afreen@ibm.com>
Thu, 2 Jul 2026 19:45:38 +0000 (01:15 +0530)
Signed-off-by: Afreen Misbah <afreen@ibm.com>
monitoring/ceph-mixin/config.libsonnet
monitoring/ceph-mixin/prometheus_alerts.libsonnet
monitoring/ceph-mixin/prometheus_alerts.yml
monitoring/ceph-mixin/tests_alerts/test_alerts.yml

index 180ebfa0903c4e8688589d098216092dc1c051bf..3bd16bf20a14917457d389353d48b3b6082e6936 100644 (file)
     // Read/Write latency is defined in ms
     NVMeoFHighClientReadLatency: 10,
     NVMeoFHighClientWriteLatency: 20,
+    //
+    // Hardware temperature thresholds in Celsius
+    HWTempMotherboardWarning: 60,
+    HWTempDIMMWarning: 80,
+    HWTempProcessorWarning: 80,
+    HWTempNVMeWarning: 70,
   },
 }
index 6173a9dd781c85005ee296985a9884dcdcfd4869..9e5e4eafd5ba43866c7bcfd3b8e86ef7c68964cc 100644 (file)
       name: 'hardware',
       rules: [
         {
-          alert: 'HardwareStorageError',
-          'for': '30s',
-          expr: 'ceph_health_detail{name="HARDWARE_STORAGE"} > 0',
+          alert: 'PowerSupplyDegraded',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="power"} == 1',
+          labels: { severity: 'warning', type: 'ceph_default' },
+          annotations: {
+            summary: 'Power supply {{ $labels.component }} degraded on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'PSU {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}.',
+          },
+        },
+        {
+          alert: 'PowerSupplyFailed',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="power"} == 2',
+          labels: { severity: 'critical', type: 'ceph_default', oid: '1.3.6.1.4.1.50495.1.2.1.13.5' },
+          annotations: {
+            summary: 'Power supply {{ $labels.component }} failed on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'PSU fault detected on {{ $labels.hostname }}. PSU {{ $labels.component }} has failed.',
+          },
+        },
+        {
+          alert: 'CoolingDegraded',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="fans"} == 1',
+          labels: { severity: 'warning', type: 'ceph_default' },
+          annotations: {
+            summary: 'Fan {{ $labels.component }} degraded on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'Fan module {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}.',
+          },
+        },
+        {
+          alert: 'CoolingFailed',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="fans"} == 2',
+          labels: { severity: 'critical', type: 'ceph_default', oid: '1.3.6.1.4.1.50495.1.2.1.13.6' },
+          annotations: {
+            summary: 'Fan {{ $labels.component }} failed on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'A cooling fault has been detected on {{ $labels.hostname }}. A cooling FAN within the enclosure has failed.',
+          },
+        },
+        {
+          alert: 'NVMeDriveDegraded',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="storage"} == 1',
+          labels: { severity: 'warning', type: 'ceph_default' },
+          annotations: {
+            summary: 'Storage device {{ $labels.component }} degraded on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'Storage device {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}.',
+          },
+        },
+        {
+          alert: 'NVMeDriveFailed',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="storage"} == 2',
           labels: { severity: 'critical', type: 'ceph_default', oid: '1.3.6.1.4.1.50495.1.2.1.13.1' },
           annotations: {
-            summary: 'Storage devices error(s) detected%(cluster)s' % $.MultiClusterSummary(),
-            description: 'Some storage devices are in error. Check `ceph health detail`.',
+            summary: 'Storage device {{ $labels.component }} failed on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'A drive fault has been detected on {{ $labels.hostname }}. Storage device {{ $labels.component }} has failed.',
           },
         },
         {
-          alert: 'HardwareMemoryError',
-          'for': '30s',
-          expr: 'ceph_health_detail{name="HARDWARE_MEMORY"} > 0',
+          alert: 'MemoryDegraded',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="memory"} == 1',
+          labels: { severity: 'warning', type: 'ceph_default' },
+          annotations: {
+            summary: 'Memory module {{ $labels.component }} degraded on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'Memory module {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}.',
+          },
+        },
+        {
+          alert: 'MemoryFailed',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="memory"} == 2',
           labels: { severity: 'critical', type: 'ceph_default', oid: '1.3.6.1.4.1.50495.1.2.1.13.2' },
           annotations: {
-            summary: 'DIMM error(s) detected%(cluster)s' % $.MultiClusterSummary(),
-            description: 'DIMM error(s) detected. Check `ceph health detail`.',
+            summary: 'Memory module {{ $labels.component }} failed on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'A memory fault has been detected on {{ $labels.hostname }}. Memory module {{ $labels.component }} has failed.',
           },
         },
         {
-          alert: 'HardwareProcessorError',
-          'for': '30s',
-          expr: 'ceph_health_detail{name="HARDWARE_PROCESSOR"} > 0',
+          alert: 'ProcessorDegraded',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="processors"} == 1',
+          labels: { severity: 'warning', type: 'ceph_default' },
+          annotations: {
+            summary: 'Processor {{ $labels.component }} degraded on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'Processor {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}.',
+          },
+        },
+        {
+          alert: 'ProcessorFailed',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="processors"} == 2',
           labels: { severity: 'critical', type: 'ceph_default', oid: '1.3.6.1.4.1.50495.1.2.1.13.3' },
           annotations: {
-            summary: 'Processor error(s) detected%(cluster)s' % $.MultiClusterSummary(),
-            description: 'Processor error(s) detected. Check `ceph health detail`.',
+            summary: 'Processor {{ $labels.component }} failed on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'A processor fault has been detected on {{ $labels.hostname }}. Processor {{ $labels.component }} has failed.',
           },
         },
         {
-          alert: 'HardwareNetworkError',
-          'for': '30s',
-          expr: 'ceph_health_detail{name="HARDWARE_NETWORK"} > 0',
+          alert: 'NetworkDegraded',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="network"} == 1',
+          labels: { severity: 'warning', type: 'ceph_default' },
+          annotations: {
+            summary: 'Network interface {{ $labels.component }} degraded on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'Network interface {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}.',
+          },
+        },
+        {
+          alert: 'NetworkFailed',
+          'for': '1m',
+          expr: 'ceph_hardware_health{category="network"} == 2',
           labels: { severity: 'critical', type: 'ceph_default', oid: '1.3.6.1.4.1.50495.1.2.1.13.4' },
           annotations: {
-            summary: 'Network error(s) detected%(cluster)s' % $.MultiClusterSummary(),
-            description: 'Network error(s) detected. Check `ceph health detail`.',
+            summary: 'Network interface {{ $labels.component }} failed on {{ $labels.hostname }}%(cluster)s' % $.MultiClusterSummary(),
+            description: 'A network fault has been detected on {{ $labels.hostname }}. Network interface {{ $labels.component }} has failed.',
           },
         },
         {
-          alert: 'HardwarePowerError',
-          'for': '30s',
-          expr: 'ceph_health_detail{name="HARDWARE_POWER"} > 0',
-          labels: { severity: 'critical', type: 'ceph_default', oid: '1.3.6.1.4.1.50495.1.2.1.13.5' },
+          alert: 'MotherboardTemperatureHigh',
+          'for': '1m',
+          expr: 'ceph_hardware_temperature_celsius{sensor_name=~".*MB_TEMP.*"} > %d' % $._config.HWTempMotherboardWarning,
+          labels: { severity: 'warning', type: 'ceph_default' },
           annotations: {
-            summary: 'Power supply error(s) detected%(cluster)s' % $.MultiClusterSummary(),
-            description: 'Power supply error(s) detected. Check `ceph health detail`.',
+            summary: 'Motherboard sensor {{ $labels.sensor_name }} above %d°C on {{ $labels.hostname }}%s' % [$._config.HWTempMotherboardWarning, $.MultiClusterSummary()],
+            description: 'Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall.',
           },
         },
         {
-          alert: 'HardwareFanError',
-          'for': '30s',
-          expr: 'ceph_health_detail{name="HARDWARE_FANS"} > 0',
-          labels: { severity: 'critical', type: 'ceph_default', oid: '1.3.6.1.4.1.50495.1.2.1.13.6' },
+          alert: 'DIMMTemperatureHigh',
+          'for': '1m',
+          expr: 'ceph_hardware_temperature_celsius{sensor_name=~".*DIMM.*_TEMP"} > %d' % $._config.HWTempDIMMWarning,
+          labels: { severity: 'warning', type: 'ceph_default' },
+          annotations: {
+            summary: 'DIMM sensor {{ $labels.sensor_name }} above %d°C on {{ $labels.hostname }}%s' % [$._config.HWTempDIMMWarning, $.MultiClusterSummary()],
+            description: 'Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall.',
+          },
+        },
+        {
+          alert: 'ProcessorTemperatureHigh',
+          'for': '1m',
+          expr: 'ceph_hardware_temperature_celsius{sensor_name=~".*CPU_TEMP"} > %d' % $._config.HWTempProcessorWarning,
+          labels: { severity: 'warning', type: 'ceph_default' },
+          annotations: {
+            summary: 'CPU sensor {{ $labels.sensor_name }} above %d°C on {{ $labels.hostname }}%s' % [$._config.HWTempProcessorWarning, $.MultiClusterSummary()],
+            description: 'Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall.',
+          },
+        },
+        {
+          alert: 'NVMeTemperatureHigh',
+          'for': '1m',
+          expr: 'ceph_hardware_temperature_celsius{sensor_name=~"NVME.*_TEMP"} > %d' % $._config.HWTempNVMeWarning,
+          labels: { severity: 'warning', type: 'ceph_default' },
           annotations: {
-            summary: 'Fan error(s) detected%(cluster)s' % $.MultiClusterSummary(),
-            description: 'Fan error(s) detected. Check `ceph health detail`.',
+            summary: 'NVMe sensor {{ $labels.sensor_name }} above %d°C on {{ $labels.hostname }}%s' % [$._config.HWTempNVMeWarning, $.MultiClusterSummary()],
+            description: 'An NVMe temperature sensor is indicating a potential cooling problem. NVMe may power down if the temperature continues to rise.',
           },
         },
       ],
index f2aa4defabde0022c65d35cfe366aaea6b32b159..4d3f6d66a61f063c4ae5c4c0920327be5b29184d 100644 (file)
@@ -650,65 +650,155 @@ groups:
           type: "ceph_default"
   - name: "hardware"
     rules:
-      - alert: "HardwareStorageError"
+      - alert: "PowerSupplyDegraded"
         annotations:
-          description: "Some storage devices are in error. Check `ceph health detail`."
-          summary: "Storage devices error(s) detected on cluster {{ $labels.cluster }}"
-        expr: "ceph_health_detail{name=\"HARDWARE_STORAGE\"} > 0"
-        for: "30s"
+          description: "PSU {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}."
+          summary: "Power supply {{ $labels.component }} degraded on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"power\"} == 1"
+        for: "1m"
+        labels:
+          severity: "warning"
+          type: "ceph_default"
+      - alert: "PowerSupplyFailed"
+        annotations:
+          description: "PSU fault detected on {{ $labels.hostname }}. PSU {{ $labels.component }} has failed."
+          summary: "Power supply {{ $labels.component }} failed on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"power\"} == 2"
+        for: "1m"
+        labels:
+          oid: "1.3.6.1.4.1.50495.1.2.1.13.5"
+          severity: "critical"
+          type: "ceph_default"
+      - alert: "CoolingDegraded"
+        annotations:
+          description: "Fan module {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}."
+          summary: "Fan {{ $labels.component }} degraded on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"fans\"} == 1"
+        for: "1m"
+        labels:
+          severity: "warning"
+          type: "ceph_default"
+      - alert: "CoolingFailed"
+        annotations:
+          description: "A cooling fault has been detected on {{ $labels.hostname }}. A cooling FAN within the enclosure has failed."
+          summary: "Fan {{ $labels.component }} failed on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"fans\"} == 2"
+        for: "1m"
+        labels:
+          oid: "1.3.6.1.4.1.50495.1.2.1.13.6"
+          severity: "critical"
+          type: "ceph_default"
+      - alert: "NVMeDriveDegraded"
+        annotations:
+          description: "Storage device {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}."
+          summary: "Storage device {{ $labels.component }} degraded on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"storage\"} == 1"
+        for: "1m"
+        labels:
+          severity: "warning"
+          type: "ceph_default"
+      - alert: "NVMeDriveFailed"
+        annotations:
+          description: "A drive fault has been detected on {{ $labels.hostname }}. Storage device {{ $labels.component }} has failed."
+          summary: "Storage device {{ $labels.component }} failed on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"storage\"} == 2"
+        for: "1m"
         labels:
           oid: "1.3.6.1.4.1.50495.1.2.1.13.1"
           severity: "critical"
           type: "ceph_default"
-      - alert: "HardwareMemoryError"
+      - alert: "MemoryDegraded"
         annotations:
-          description: "DIMM error(s) detected. Check `ceph health detail`."
-          summary: "DIMM error(s) detected on cluster {{ $labels.cluster }}"
-        expr: "ceph_health_detail{name=\"HARDWARE_MEMORY\"} > 0"
-        for: "30s"
+          description: "Memory module {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}."
+          summary: "Memory module {{ $labels.component }} degraded on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"memory\"} == 1"
+        for: "1m"
+        labels:
+          severity: "warning"
+          type: "ceph_default"
+      - alert: "MemoryFailed"
+        annotations:
+          description: "A memory fault has been detected on {{ $labels.hostname }}. Memory module {{ $labels.component }} has failed."
+          summary: "Memory module {{ $labels.component }} failed on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"memory\"} == 2"
+        for: "1m"
         labels:
           oid: "1.3.6.1.4.1.50495.1.2.1.13.2"
           severity: "critical"
           type: "ceph_default"
-      - alert: "HardwareProcessorError"
+      - alert: "ProcessorDegraded"
         annotations:
-          description: "Processor error(s) detected. Check `ceph health detail`."
-          summary: "Processor error(s) detected on cluster {{ $labels.cluster }}"
-        expr: "ceph_health_detail{name=\"HARDWARE_PROCESSOR\"} > 0"
-        for: "30s"
+          description: "Processor {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}."
+          summary: "Processor {{ $labels.component }} degraded on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"processors\"} == 1"
+        for: "1m"
+        labels:
+          severity: "warning"
+          type: "ceph_default"
+      - alert: "ProcessorFailed"
+        annotations:
+          description: "A processor fault has been detected on {{ $labels.hostname }}. Processor {{ $labels.component }} has failed."
+          summary: "Processor {{ $labels.component }} failed on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"processors\"} == 2"
+        for: "1m"
         labels:
           oid: "1.3.6.1.4.1.50495.1.2.1.13.3"
           severity: "critical"
           type: "ceph_default"
-      - alert: "HardwareNetworkError"
+      - alert: "NetworkDegraded"
         annotations:
-          description: "Network error(s) detected. Check `ceph health detail`."
-          summary: "Network error(s) detected on cluster {{ $labels.cluster }}"
-        expr: "ceph_health_detail{name=\"HARDWARE_NETWORK\"} > 0"
-        for: "30s"
+          description: "Network interface {{ $labels.component }} is in a degraded state on {{ $labels.hostname }}."
+          summary: "Network interface {{ $labels.component }} degraded on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"network\"} == 1"
+        for: "1m"
+        labels:
+          severity: "warning"
+          type: "ceph_default"
+      - alert: "NetworkFailed"
+        annotations:
+          description: "A network fault has been detected on {{ $labels.hostname }}. Network interface {{ $labels.component }} has failed."
+          summary: "Network interface {{ $labels.component }} failed on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_health{category=\"network\"} == 2"
+        for: "1m"
         labels:
           oid: "1.3.6.1.4.1.50495.1.2.1.13.4"
           severity: "critical"
           type: "ceph_default"
-      - alert: "HardwarePowerError"
+      - alert: "MotherboardTemperatureHigh"
         annotations:
-          description: "Power supply error(s) detected. Check `ceph health detail`."
-          summary: "Power supply error(s) detected on cluster {{ $labels.cluster }}"
-        expr: "ceph_health_detail{name=\"HARDWARE_POWER\"} > 0"
-        for: "30s"
+          description: "Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall."
+          summary: "Motherboard sensor {{ $labels.sensor_name }} above 60°C on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_temperature_celsius{sensor_name=~\".*MB_TEMP.*\"} > 60"
+        for: "1m"
         labels:
-          oid: "1.3.6.1.4.1.50495.1.2.1.13.5"
-          severity: "critical"
+          severity: "warning"
           type: "ceph_default"
-      - alert: "HardwareFanError"
+      - alert: "DIMMTemperatureHigh"
         annotations:
-          description: "Fan error(s) detected. Check `ceph health detail`."
-          summary: "Fan error(s) detected on cluster {{ $labels.cluster }}"
-        expr: "ceph_health_detail{name=\"HARDWARE_FANS\"} > 0"
-        for: "30s"
+          description: "Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall."
+          summary: "DIMM sensor {{ $labels.sensor_name }} above 80°C on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_temperature_celsius{sensor_name=~\".*DIMM.*_TEMP\"} > 80"
+        for: "1m"
         labels:
-          oid: "1.3.6.1.4.1.50495.1.2.1.13.6"
-          severity: "critical"
+          severity: "warning"
+          type: "ceph_default"
+      - alert: "ProcessorTemperatureHigh"
+        annotations:
+          description: "Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall."
+          summary: "CPU sensor {{ $labels.sensor_name }} above 80°C on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_temperature_celsius{sensor_name=~\".*CPU_TEMP\"} > 80"
+        for: "1m"
+        labels:
+          severity: "warning"
+          type: "ceph_default"
+      - alert: "NVMeTemperatureHigh"
+        annotations:
+          description: "An NVMe temperature sensor is indicating a potential cooling problem. NVMe may power down if the temperature continues to rise."
+          summary: "NVMe sensor {{ $labels.sensor_name }} above 70°C on {{ $labels.hostname }} on cluster {{ $labels.cluster }}"
+        expr: "ceph_hardware_temperature_celsius{sensor_name=~\"NVME.*_TEMP\"} > 70"
+        for: "1m"
+        labels:
+          severity: "warning"
           type: "ceph_default"
   - name: "PrometheusServer"
     rules:
index 6a4c2cd207622ec3873394123d75c96b18037fe3..d40963ed1e66e6aec4faf277b1a0c1cf8ffdbb07 100644 (file)
@@ -2087,156 +2087,440 @@ tests:
            summary: "The replication network usage on cluster mycluster has been increased over 80% in the last 30 minutes. Review the number of images being replicated. This alert will be cleaned automatically after 30 minutes"
            description: "Detected a heavy increase in bandwidth for rbd replications (over 80%) in the last 30 min. This might not be a problem, but it is good to review the number of images being replicated simultaneously"
 
- - interval: 30s
+ # Power supply degraded
+ - interval: 1m
    input_series:
-    - series: 'ceph_health_detail{name="HARDWARE_STORAGE", cluster="mycluster"}'
-      values: '1+0x40'
+    - series: 'ceph_hardware_health{category="power",component="PSU0",hostname="node1",cluster="mycluster"}'
+      values: '1 1 1 1 1 1 1 1 1'
    promql_expr_test:
-     - expr: ceph_health_detail{name="HARDWARE_STORAGE"} > 0
+     - expr: ceph_hardware_health{category="power"} == 1
        eval_time: 2m
        exp_samples:
-         - labels: '{__name__="ceph_health_detail", name="HARDWARE_STORAGE", cluster="mycluster"}'
+         - labels: 'ceph_hardware_health{category="power",component="PSU0",hostname="node1",cluster="mycluster"}'
            value: 1
    alert_rule_test:
     - eval_time: 1m
-      alertname: HardwareStorageError
+      alertname: PowerSupplyDegraded
     - eval_time: 5m
-      alertname: HardwareStorageError
+      alertname: PowerSupplyDegraded
       exp_alerts:
       - exp_labels:
-          name: HARDWARE_STORAGE
+          category: power
+          component: PSU0
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "Power supply PSU0 degraded on node1 on cluster mycluster"
+          description: "PSU PSU0 is in a degraded state on node1."
+ # Power supply failed
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_health{category="power",component="PSU1",hostname="node2",cluster="mycluster"}'
+      values: '2 2 2 2 2 2 2 2 2'
+   promql_expr_test:
+     - expr: ceph_hardware_health{category="power"} == 2
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_health{category="power",component="PSU1",hostname="node2",cluster="mycluster"}'
+           value: 2
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: PowerSupplyFailed
+    - eval_time: 5m
+      alertname: PowerSupplyFailed
+      exp_alerts:
+      - exp_labels:
+          category: power
+          component: PSU1
+          hostname: node2
           severity: critical
           cluster: mycluster
           type: ceph_default
-          oid: 1.3.6.1.4.1.50495.1.2.1.13.1
+          oid: 1.3.6.1.4.1.50495.1.2.1.13.5
         exp_annotations:
-          summary: Storage devices error(s) detected on cluster mycluster
-          description: "Some storage devices are in error. Check `ceph health detail`."
- - interval: 30s
+          summary: "Power supply PSU1 failed on node2 on cluster mycluster"
+          description: "PSU fault detected on node2. PSU PSU1 has failed."
+ # Cooling degraded
+ - interval: 1m
    input_series:
-    - series: 'ceph_health_detail{name="HARDWARE_MEMORY", cluster="mycluster"}'
-      values: '1+0x40'
+    - series: 'ceph_hardware_health{category="fans",component="FAN0",hostname="node1",cluster="mycluster"}'
+      values: '1 1 1 1 1 1 1 1 1'
    promql_expr_test:
-     - expr: ceph_health_detail{name="HARDWARE_MEMORY"} > 0
+     - expr: ceph_hardware_health{category="fans"} == 1
        eval_time: 2m
        exp_samples:
-         - labels: '{__name__="ceph_health_detail", name="HARDWARE_MEMORY", cluster="mycluster"}'
+         - labels: 'ceph_hardware_health{category="fans",component="FAN0",hostname="node1",cluster="mycluster"}'
            value: 1
    alert_rule_test:
     - eval_time: 1m
-      alertname: HardwareMemoryError
+      alertname: CoolingDegraded
     - eval_time: 5m
-      alertname: HardwareMemoryError
+      alertname: CoolingDegraded
       exp_alerts:
       - exp_labels:
-          name: HARDWARE_MEMORY
+          category: fans
+          component: FAN0
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "Fan FAN0 degraded on node1 on cluster mycluster"
+          description: "Fan module FAN0 is in a degraded state on node1."
+ # Cooling failed
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_health{category="fans",component="FAN1",hostname="node2",cluster="mycluster"}'
+      values: '2 2 2 2 2 2 2 2 2'
+   promql_expr_test:
+     - expr: ceph_hardware_health{category="fans"} == 2
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_health{category="fans",component="FAN1",hostname="node2",cluster="mycluster"}'
+           value: 2
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: CoolingFailed
+    - eval_time: 5m
+      alertname: CoolingFailed
+      exp_alerts:
+      - exp_labels:
+          category: fans
+          component: FAN1
+          hostname: node2
           severity: critical
           cluster: mycluster
           type: ceph_default
-          oid: 1.3.6.1.4.1.50495.1.2.1.13.2
+          oid: 1.3.6.1.4.1.50495.1.2.1.13.6
         exp_annotations:
-          summary: DIMM error(s) detected on cluster mycluster
-          description: "DIMM error(s) detected. Check `ceph health detail`."
- - interval: 30s
+          summary: "Fan FAN1 failed on node2 on cluster mycluster"
+          description: "A cooling fault has been detected on node2. A cooling FAN within the enclosure has failed."
+ # NVMe drive degraded
+ - interval: 1m
    input_series:
-    - series: 'ceph_health_detail{name="HARDWARE_PROCESSOR", cluster="mycluster"}'
-      values: '1+0x40'
+    - series: 'ceph_hardware_health{category="storage",component="nvme0n1",hostname="node1",cluster="mycluster"}'
+      values: '1 1 1 1 1 1 1 1 1'
    promql_expr_test:
-     - expr: ceph_health_detail{name="HARDWARE_PROCESSOR"} > 0
+     - expr: ceph_hardware_health{category="storage"} == 1
        eval_time: 2m
        exp_samples:
-         - labels: '{__name__="ceph_health_detail", name="HARDWARE_PROCESSOR", cluster="mycluster"}'
+         - labels: 'ceph_hardware_health{category="storage",component="nvme0n1",hostname="node1",cluster="mycluster"}'
            value: 1
    alert_rule_test:
     - eval_time: 1m
-      alertname: HardwareProcessorError
+      alertname: NVMeDriveDegraded
     - eval_time: 5m
-      alertname: HardwareProcessorError
+      alertname: NVMeDriveDegraded
       exp_alerts:
       - exp_labels:
-          name: HARDWARE_PROCESSOR
+          category: storage
+          component: nvme0n1
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "Storage device nvme0n1 degraded on node1 on cluster mycluster"
+          description: "Storage device nvme0n1 is in a degraded state on node1."
+ # NVMe drive failed
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_health{category="storage",component="nvme1n1",hostname="node2",cluster="mycluster"}'
+      values: '2 2 2 2 2 2 2 2 2'
+   promql_expr_test:
+     - expr: ceph_hardware_health{category="storage"} == 2
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_health{category="storage",component="nvme1n1",hostname="node2",cluster="mycluster"}'
+           value: 2
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: NVMeDriveFailed
+    - eval_time: 5m
+      alertname: NVMeDriveFailed
+      exp_alerts:
+      - exp_labels:
+          category: storage
+          component: nvme1n1
+          hostname: node2
           severity: critical
           cluster: mycluster
           type: ceph_default
-          oid: 1.3.6.1.4.1.50495.1.2.1.13.3
+          oid: 1.3.6.1.4.1.50495.1.2.1.13.1
         exp_annotations:
-          summary: Processor error(s) detected on cluster mycluster
-          description: "Processor error(s) detected. Check `ceph health detail`."
- - interval: 30s
+          summary: "Storage device nvme1n1 failed on node2 on cluster mycluster"
+          description: "A drive fault has been detected on node2. Storage device nvme1n1 has failed."
+ # Memory degraded
+ - interval: 1m
    input_series:
-    - series: 'ceph_health_detail{name="HARDWARE_NETWORK", cluster="mycluster"}'
-      values: '1+0x40'
+    - series: 'ceph_hardware_health{category="memory",component="DIMM_A0",hostname="node1",cluster="mycluster"}'
+      values: '1 1 1 1 1 1 1 1 1'
    promql_expr_test:
-     - expr: ceph_health_detail{name="HARDWARE_NETWORK"} > 0
+     - expr: ceph_hardware_health{category="memory"} == 1
        eval_time: 2m
        exp_samples:
-         - labels: '{__name__="ceph_health_detail", name="HARDWARE_NETWORK", cluster="mycluster"}'
+         - labels: 'ceph_hardware_health{category="memory",component="DIMM_A0",hostname="node1",cluster="mycluster"}'
            value: 1
    alert_rule_test:
     - eval_time: 1m
-      alertname: HardwareNetworkError
+      alertname: MemoryDegraded
+    - eval_time: 5m
+      alertname: MemoryDegraded
+      exp_alerts:
+      - exp_labels:
+          category: memory
+          component: DIMM_A0
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "Memory module DIMM_A0 degraded on node1 on cluster mycluster"
+          description: "Memory module DIMM_A0 is in a degraded state on node1."
+ # Memory failed
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_health{category="memory",component="DIMM_B0",hostname="node2",cluster="mycluster"}'
+      values: '2 2 2 2 2 2 2 2 2'
+   promql_expr_test:
+     - expr: ceph_hardware_health{category="memory"} == 2
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_health{category="memory",component="DIMM_B0",hostname="node2",cluster="mycluster"}'
+           value: 2
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: MemoryFailed
     - eval_time: 5m
-      alertname: HardwareNetworkError
+      alertname: MemoryFailed
       exp_alerts:
       - exp_labels:
-          name: HARDWARE_NETWORK
+          category: memory
+          component: DIMM_B0
+          hostname: node2
           severity: critical
           cluster: mycluster
           type: ceph_default
-          oid: 1.3.6.1.4.1.50495.1.2.1.13.4
+          oid: 1.3.6.1.4.1.50495.1.2.1.13.2
         exp_annotations:
-          summary: Network error(s) detected on cluster mycluster
-          description: "Network error(s) detected. Check `ceph health detail`."
- - interval: 30s
+          summary: "Memory module DIMM_B0 failed on node2 on cluster mycluster"
+          description: "A memory fault has been detected on node2. Memory module DIMM_B0 has failed."
+ # Processor degraded
+ - interval: 1m
    input_series:
-    - series: 'ceph_health_detail{name="HARDWARE_POWER", cluster="mycluster"}'
-      values: '1+0x40'
+    - series: 'ceph_hardware_health{category="processors",component="CPU0",hostname="node1",cluster="mycluster"}'
+      values: '1 1 1 1 1 1 1 1 1'
    promql_expr_test:
-     - expr: ceph_health_detail{name="HARDWARE_POWER"} > 0
+     - expr: ceph_hardware_health{category="processors"} == 1
        eval_time: 2m
        exp_samples:
-         - labels: '{__name__="ceph_health_detail", name="HARDWARE_POWER", cluster="mycluster"}'
+         - labels: 'ceph_hardware_health{category="processors",component="CPU0",hostname="node1",cluster="mycluster"}'
            value: 1
    alert_rule_test:
     - eval_time: 1m
-      alertname: HardwarePowerError
+      alertname: ProcessorDegraded
+    - eval_time: 5m
+      alertname: ProcessorDegraded
+      exp_alerts:
+      - exp_labels:
+          category: processors
+          component: CPU0
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "Processor CPU0 degraded on node1 on cluster mycluster"
+          description: "Processor CPU0 is in a degraded state on node1."
+ # Processor failed
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_health{category="processors",component="CPU1",hostname="node2",cluster="mycluster"}'
+      values: '2 2 2 2 2 2 2 2 2'
+   promql_expr_test:
+     - expr: ceph_hardware_health{category="processors"} == 2
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_health{category="processors",component="CPU1",hostname="node2",cluster="mycluster"}'
+           value: 2
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: ProcessorFailed
     - eval_time: 5m
-      alertname: HardwarePowerError
+      alertname: ProcessorFailed
       exp_alerts:
       - exp_labels:
-          name: HARDWARE_POWER
+          category: processors
+          component: CPU1
+          hostname: node2
           severity: critical
           cluster: mycluster
           type: ceph_default
-          oid: 1.3.6.1.4.1.50495.1.2.1.13.5
+          oid: 1.3.6.1.4.1.50495.1.2.1.13.3
         exp_annotations:
-          summary: Power supply error(s) detected on cluster mycluster
-          description: "Power supply error(s) detected. Check `ceph health detail`."
- - interval: 30s
+          summary: "Processor CPU1 failed on node2 on cluster mycluster"
+          description: "A processor fault has been detected on node2. Processor CPU1 has failed."
+ # Network degraded
+ - interval: 1m
    input_series:
-    - series: 'ceph_health_detail{name="HARDWARE_FANS", cluster="mycluster"}'
-      values: '1+0x40'
+    - series: 'ceph_hardware_health{category="network",component="eth0",hostname="node1",cluster="mycluster"}'
+      values: '1 1 1 1 1 1 1 1 1'
    promql_expr_test:
-     - expr: ceph_health_detail{name="HARDWARE_FANS"} > 0
+     - expr: ceph_hardware_health{category="network"} == 1
        eval_time: 2m
        exp_samples:
-         - labels: '{__name__="ceph_health_detail", name="HARDWARE_FANS", cluster="mycluster"}'
+         - labels: 'ceph_hardware_health{category="network",component="eth0",hostname="node1",cluster="mycluster"}'
            value: 1
    alert_rule_test:
     - eval_time: 1m
-      alertname: HardwareFanError
+      alertname: NetworkDegraded
+    - eval_time: 5m
+      alertname: NetworkDegraded
+      exp_alerts:
+      - exp_labels:
+          category: network
+          component: eth0
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "Network interface eth0 degraded on node1 on cluster mycluster"
+          description: "Network interface eth0 is in a degraded state on node1."
+ # Network failed
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_health{category="network",component="eth1",hostname="node2",cluster="mycluster"}'
+      values: '2 2 2 2 2 2 2 2 2'
+   promql_expr_test:
+     - expr: ceph_hardware_health{category="network"} == 2
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_health{category="network",component="eth1",hostname="node2",cluster="mycluster"}'
+           value: 2
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: NetworkFailed
     - eval_time: 5m
-      alertname: HardwareFanError
+      alertname: NetworkFailed
       exp_alerts:
       - exp_labels:
-          name: HARDWARE_FANS
+          category: network
+          component: eth1
+          hostname: node2
           severity: critical
           cluster: mycluster
           type: ceph_default
-          oid: 1.3.6.1.4.1.50495.1.2.1.13.6
+          oid: 1.3.6.1.4.1.50495.1.2.1.13.4
+        exp_annotations:
+          summary: "Network interface eth1 failed on node2 on cluster mycluster"
+          description: "A network fault has been detected on node2. Network interface eth1 has failed."
+ # Motherboard temperature high
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_temperature_celsius{sensor_name="MB_TEMP1",hostname="node1",cluster="mycluster"}'
+      values: '65 65 65 65 65 65 65 65 65'
+   promql_expr_test:
+     - expr: ceph_hardware_temperature_celsius{sensor_name=~".*MB_TEMP.*"} > 60
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_temperature_celsius{sensor_name="MB_TEMP1",hostname="node1",cluster="mycluster"}'
+           value: 65
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: MotherboardTemperatureHigh
+    - eval_time: 5m
+      alertname: MotherboardTemperatureHigh
+      exp_alerts:
+      - exp_labels:
+          sensor_name: MB_TEMP1
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "Motherboard sensor MB_TEMP1 above 60°C on node1 on cluster mycluster"
+          description: "Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall."
+ # DIMM temperature high
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_temperature_celsius{sensor_name="DIMM_A0_TEMP",hostname="node1",cluster="mycluster"}'
+      values: '85 85 85 85 85 85 85 85 85'
+   promql_expr_test:
+     - expr: ceph_hardware_temperature_celsius{sensor_name=~".*DIMM.*_TEMP"} > 80
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_temperature_celsius{sensor_name="DIMM_A0_TEMP",hostname="node1",cluster="mycluster"}'
+           value: 85
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: DIMMTemperatureHigh
+    - eval_time: 5m
+      alertname: DIMMTemperatureHigh
+      exp_alerts:
+      - exp_labels:
+          sensor_name: DIMM_A0_TEMP
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "DIMM sensor DIMM_A0_TEMP above 80°C on node1 on cluster mycluster"
+          description: "Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall."
+ # Processor temperature high
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_temperature_celsius{sensor_name="CPU_TEMP",hostname="node1",cluster="mycluster"}'
+      values: '85 85 85 85 85 85 85 85 85'
+   promql_expr_test:
+     - expr: ceph_hardware_temperature_celsius{sensor_name=~".*CPU_TEMP"} > 80
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_temperature_celsius{sensor_name="CPU_TEMP",hostname="node1",cluster="mycluster"}'
+           value: 85
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: ProcessorTemperatureHigh
+    - eval_time: 5m
+      alertname: ProcessorTemperatureHigh
+      exp_alerts:
+      - exp_labels:
+          sensor_name: CPU_TEMP
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
+        exp_annotations:
+          summary: "CPU sensor CPU_TEMP above 80°C on node1 on cluster mycluster"
+          description: "Prolonged high temperatures could lead to platform instability. Investigate cooling issues and hot-spots in the server room/hall."
+ # NVMe temperature high
+ - interval: 1m
+   input_series:
+    - series: 'ceph_hardware_temperature_celsius{sensor_name="NVME0_TEMP",hostname="node1",cluster="mycluster"}'
+      values: '75 75 75 75 75 75 75 75 75'
+   promql_expr_test:
+     - expr: ceph_hardware_temperature_celsius{sensor_name=~"NVME.*_TEMP"} > 70
+       eval_time: 2m
+       exp_samples:
+         - labels: 'ceph_hardware_temperature_celsius{sensor_name="NVME0_TEMP",hostname="node1",cluster="mycluster"}'
+           value: 75
+   alert_rule_test:
+    - eval_time: 1m
+      alertname: NVMeTemperatureHigh
+    - eval_time: 5m
+      alertname: NVMeTemperatureHigh
+      exp_alerts:
+      - exp_labels:
+          sensor_name: NVME0_TEMP
+          hostname: node1
+          severity: warning
+          cluster: mycluster
+          type: ceph_default
         exp_annotations:
-          summary: Fan error(s) detected on cluster mycluster
-          description: "Fan error(s) detected. Check `ceph health detail`."
+          summary: "NVMe sensor NVME0_TEMP above 70°C on node1 on cluster mycluster"
+          description: "An NVMe temperature sensor is indicating a potential cooling problem. NVMe may power down if the temperature continues to rise."
 
 # nvmeof Tests