+ Network Configuration Reference
+=================================
+
+Network configuration is critical for building a high performance Ceph cluster.
+The Ceph cluster does not perform request routing or dispatching on behalf of
+the client. Instead, Ceph clients (i.e., block device, CephFS, REST gateway)
+make requests directly to OSDs. Ceph OSDs perform data replication on behalf of
+clients, which means replication and other factors impose additional loads on
+Ceph cluster networks.
+
+Our 5-minute Quick Start provides a trivial `Ceph configuration file`_ that sets
+monitor IP addresses and daemon host names only. The quick start configuration
+assumes a single "public" network. Ceph functions just fine with a public
+network only, but you may see significant performance improvement with a second
+network in a large cluster.
+
+We recommend running a Ceph cluster with two networks: a public (front-side)
+network and a cluster (back-side) network. To support two networks, your hosts
+need to have more than one NIC. See `Hardware Recommendations -  Networks`_ for
+additional details.
+
+.. ditaa::
+                               +-------------+
+                               | Ceph Client |
+                               +----*--*-----+
+                                    |  ^
+                            Request |  : Response
+                                    v  |
+ /----------------------------------*--*-------------------------------------\
+ |                              Public Network                               |
+ \---*--*------------*--*-------------*--*------------*--*------------*--*---/
+     ^  ^            ^  ^             ^  ^            ^  ^            ^  ^
+     |  |            |  |             |  |            |  |            |  |
+     |  :            |  :             |  :            |  :            |  :
+     v  v            v  v             v  v            v  v            v  v
+ +---*--*---+    +---*--*---+     +---*--*---+    +---*--*---+    +---*--*---+
+ | Ceph MON |    | Ceph MDS |     | Ceph OSD |    | Ceph OSD |    | Ceph OSD |
+ +----------+    +----------+     +---*--*---+    +---*--*---+    +---*--*---+
+                                      ^  ^            ^  ^            ^  ^
+     The cluster network relieves     |  |            |  |            |  |
+     OSD replication and heartbeat    |  :            |  :            |  :
+     traffic from the public network. v  v            v  v            v  v
+ /------------------------------------*--*------------*--*------------*--*---\
+ |   cCCC                      Cluster Network                               |
+ \---------------------------------------------------------------------------/
+
+
+There are several reasons to consider operating two separate networks:
+
+#. **Peformance:** OSDs handle data replication for the clients. When OSDs 
+   replicate data more than once, the network load between OSDs easily dwarfs 
+   the network load between clients and the Ceph cluster. This can introduce 
+   latency and create a performance problem. Recovery and rebalacing can 
+   also introduce significant latency on the public network. See `How Ceph 
+   Scales`_ for additional details on how Ceph replicates data. See 
+   `Monitor / OSD Interaction`_  for details on heartbeat traffic.
+
+#. **Security**: While most people are generally civil, a very tiny segment of 
+   the population likes to engage in what's known as a Denial of Service (DoS) 
+   attack. When traffic between OSDs gets disrupted, placement groups may no
+   longer reflect an ``active + clean`` state, which may prevent users from 
+   reading and writing data. A great way to defeat this type of attack is to 
+   maintain a completely separate cluster network that doesn't connect directly 
+   to the internet. Also, consider using `Message Signatures`_ to defeat 
+   spoofing attacks.
+
+
+IP Tables
+=========
+
+Before configuring your IP tables, check the default ``iptables`` configuration.
+::
+
+       sudo iptables -L
+
+Some Linux distributions include rules that reject all inbound requests
+except SSH from all network interfaces. For example:: 
+
+       REJECT all -- anywhere anywhere reject-with icmp-host-prohibited
+
+You will need to delete these rules on both your public and cluster networks
+initially, and replace them with appropriate rules when you are ready to 
+harden the ports on your cluster hosts.
+
+
+Monitor IP Tables
+-----------------
+
+Monitors listen on port 6789 by default. Additionally, monitors always operate
+on the public network. When you add the rule using the example below, make
+sure you replace ``{iface}`` with the public network interface (e.g., ``eth0``,
+``eth1``, etc.), ``{ip-address}`` with  the IP address of the public network and
+``{netmask}`` with the netmask for the public network. ::
+
+   sudo iptables -A INPUT -i {iface} -p tcp -s {ip-address}/{netmask} --dport 6789 -j ACCEPT
+
+
+MDS IP Tables
+-------------
+
+Metadata servers listen on the first available port on the public network
+beginning at port 6800. Ensure that you open one port beginning at port 6800 for
+each metadata server that runs on the host. When you add the rule using the
+example below, make sure you replace ``{iface}`` with the public network
+interface (e.g., ``eth0``, ``eth1``, etc.), ``{ip-address}`` with the IP address
+of the public network and ``{netmask}`` with the netmask of the public network.
+
+For example:: 
+
+       sudo iptables -A INPUT -i {iface} -m multiport -p tcp -s {ip-address}/{netmask} --dports 6800:6810 -j ACCEPT
+
+
+OSD IP Tables
+-------------
+
+OSDs servers listen on the first available port beginning at port 6800. Ensure
+that you open one port beginning at port 6800 for each OSD server that runs on
+the host. Ports are host-specific, so you don't need to open any more ports than
+the number of Ceph daemons running on that host. You may consider opening a few
+additional ports in case a daemon fails and restarts without letting go of the
+port such that the restarted daemon binds to a new port. 
+
+If you set up separate public and cluster networks, you must add rules for both
+the public network and the cluster network, because clients will connect using
+the public network and other OSDs will connect using the cluster network. When
+you add the rule using the example below, make sure you replace ``{iface}`` with
+the network interface (e.g., ``eth0``, ``eth1``, etc.), ``{ip-address}`` with
+the IP address and ``{netmask}`` with the netmask of the public or cluster
+network. For example:: 
+
+       sudo iptables -A INPUT -i {iface}  -m multiport -p tcp -s {ip-address}/{netmask} --dports 6800:6810 -j ACCEPT
+
+
+.. tip:: If you run metadata servers on the same host as the OSDs,
+   you can consolidate the public network configuration step. Ensure
+   you open a port for each daemon.
+
+
+
+Ceph Networks
+=============
+
+To configure Ceph networks, you must add a network configuration to the
+``[global]`` section of the configuration file. Our 5-minute Quick Start
+provides a trivial `Ceph configuration file`_ that assumes one public network
+with client and server on the same network and subnet. Ceph functions just fine
+with a public network only. However, Ceph  allows you to establish much more
+specific criteria, including multiple network IP addresses and subnet masks
+for your public network. You can also establish a separate cluster network
+to handle OSD heartbeat, object replication and recovery traffic. 
+
+.. tip:: If you specify more than one IP address and subnet mask for
+   either the public or the cluster network, the subnets within the network
+   must be capable of routing to each other. Additionally, make sure you
+   include each IP address/subnet in your IP tables and open ports for them
+   as necessary.
+
+.. note:: Ceph uses `CIDR`_ notation for subnets (e.g., ``10.20.30.40/24``).
+
+
+Public Network
+--------------
+
+To configure a public network, add the following option to the ``[global]``
+section of your Ceph configuration file. 
+
+.. code-block:: ini
+
+       [global]
+               ...
+               public network = {public-network-ip-address/netmask}
+
+
+Cluster Network
+---------------
+
+If you declare a cluster network, OSDs will route heartbeat, object replication
+and recovery traffic over the cluster network. This may improve performance
+compared to using a single network. To configure a cluster network, add the
+following option to the ``[global]`` section of your Ceph configuration file. 
+
+.. code-block:: ini
+
+       [global]
+               ...
+               cluster network = {enter cluster-network-ip-address/netmask}
+
+We prefer that the cluster network is **NOT** reachable from the public network
+or the Internet for added security.
+
+
+Ceph Daemons
+============
+
+Ceph has one network configuration requirement that applies to all daemons: the
+Ceph configuration file **MUST** specify the ``host`` for each daemon. Ceph also
+requires that a Ceph configuration file specify the monitor IP address and its
+port.
+
+.. important:: Some deployment tools (e.g., ``ceph-deploy``, Chef) may create a
+   configuration file for you. **DO NOT** set these values if the deployment 
+   tool does it for you.
+
+.. tip:: The ``host`` setting is the short name of the host (i.e., not 
+   an fqdn). It is **NOT** an IP address either.  Enter ``hostname -s`` on 
+   the command line to retrieve the name of the host.
+
+
+.. code-block:: ini
+
+       [mon.a]
+       
+               host = {hostname}
+               mon addr = {ip-address}:6789
+
+       [osd.0]
+               host = {hostname}
+
+
+You do not have to set the host IP address for a daemon. If you have a static IP
+configuration and both public and cluster networks running, the Ceph
+configuration file may specify the IP address of the host for each daemon. To
+set a static IP address for a daemon, the following option(s) should appear in
+the daemon instance sections of your ``ceph.conf`` file.
+
+.. code-block:: ini
+
+       [osd.0]
+               public addr = {host-public-ip-address}
+               cluster addr = {host-cluster-ip-address}
+
+
+.. topic:: One NIC OSD in a Two Network Cluster
+
+   Generally, we do not recommend deploying an OSD host with a single NIC in a 
+   cluster with two networks. However, you may accomplish this by forcing the 
+   OSD host to operate on the public network by adding a ``public addr`` entry
+   to the ``[osd.n]`` section of the Ceph configuration file, where ``n`` 
+   refers to the number of the OSD with one NIC. Additionally, the public
+   network and cluster network must be able to route traffic to each other, 
+   which we don't recommend for security reasons.
+
+
+Network Config Settings
+=======================
+
+Network configuration settings are not required. Ceph assumes a public network
+with all hosts operating on it unless you specifically configure a cluster 
+network.
+
+Public Network
+--------------
+
+The public network configuration allows you specifically define IP addresses
+and subnets for the public network. You may specifically assign static IP 
+addresses or override ``public network`` settings using the ``public addr``
+setting for a specific daemon.
+
+``public network``
+
+:Description: The IP address and netmask of the public (front-side) network 
+              (e.g., ``10.20.30.40/24``). Set in ``[global]``. You may specify
+              comma-delimited subnets.
+
+:Type: ``{ip-address}/{netmask} [, {ip-address}/{netmask}]``
+:Required: No
+:Default: N/A
+
+
+``public addr``
+
+:Description: The IP address for the public (front-side) network. 
+              Set for each daemon.
+
+:Type: IP Address
+:Required: No
+:Default: N/A
+
+
+
+Cluster Network
+---------------
+
+The cluster network configuration allows you to declare a cluster network, and
+specifically define IP addresses and subnets for the cluster network. You may
+specifically assign static IP  addresses or override ``cluster network``
+settings using the ``cluster addr`` setting for specific OSD daemons.
+
+
+``cluster network``
+
+:Description: The IP address and netmask of the cluster (back-side) network 
+              (e.g., ``10.20.30.41/24``).  Set in ``[global]``. You may specify
+              comma-delimited subnets.
+
+:Type: ``{ip-address}/{netmask} [, {ip-address}/{netmask}]``
+:Required: No
+:Default: N/A
+
+
+``cluster addr``
+
+:Description: The IP address for the cluster (back-side) network. 
+              Set for each daemon.
+
+:Type: Address
+:Required: No
+:Default: N/A
+
+
+Hosts
+-----
+
+Ceph expects at least one monitor declared in the Ceph configuration file, with
+a ``mon host`` setting under each declared monitor. Ceph expects a ``host``
+setting under each declared metadata server and OSD in the  Ceph configuration
+file.
+
+
+``mon host``
+
+:Description: A list of ``{hostname}:{port}`` entries that clients can use to 
+              connect to a Ceph monitor. If not set, Ceph searches ``[mon.*]`` 
+              sections. 
+
+:Type: String
+:Required: No
+:Default: N/A
+
+
+``host``
+
+:Description: The hostname. Use this setting for specific daemon instances 
+              (e.g., ``[osd.0]``).
+
+:Type: String
+:Required: Yes, for daemon instances.
+:Default: ``localhost``
+
+.. tip:: Do not use ``localhost``. To get your host name, execute 
+         ``hostname -s`` on your command line and use the name of your host 
+         (to the first period, not the fully-qualified domain name).
+
+.. important:: You should not specify any value for ``host`` when using a third
+               party deployment system that retrieves the host name for you.
+
+
+
+
+.. _How Ceph Scales: ../../../architecture#how-ceph-scales
+.. _Hardware Recommendations - Networks: ../../../install/hardware-recommendations#networks
+.. _Ceph configuration file: ../../../start/quick-start/#add-a-configuration-file
+.. _hardware recommendations: ../../../install/hardware-recommendations
+.. _Monitor / OSD Interaction: ../mon-osd-interaction
+.. _Message Signatures: ../auth-config-ref#signatures
+.. _CIDR: http://en.wikipedia.org/wiki/Classless_Inter-Domain_Routing